API
api-cb logo
API-Camille Bauer Division of
Absolute Process Instruments, Inc.

Signal Conditioners, Signal Isolators, Process Transmitters
Electrical Power Monitors, Electrical Power Transducers,
Rotary Position Sensors
apicb API CecompGauges APCS products Rheintacho products
Temperature & Universal Transmitters
Sineax V 611 Ultra-Slim Temperature Transmitter
Input: Thermocouple or RTD

Output: 4-20 mA or 20-4 mA
  • 9 mm (0.35") wide
  • PC Programmable
  • Reverse Output Capable (20-4 mA)
  • 100 Ohm RTD, 2, 3, or 4-wire
  • T/C J, K, T, E, R, S,N, B, L, U, W5, W3
  • Input Linearization
  • Non-Isolated
  • Internal or External CJC
  • Supply Voltage:12-30 VDC from Output Loop
CE logo Data Sheet
Instructions
CE Declaration
V600Plus Software
Sineax V611
Top of page
Sineax V 608 Temperature Transmitter
Input: Thermocouple, RTD

Output: 4-20 mA
  • PC Programmable
  • Programmable Sensor Fault Response
  • Non-Isolated
  • 12-30 VDC Loop-Powered
CE logo Data Sheet
Instructions
CE Declaration
V600Plus Software
V608
Top of page
Sineax V 624 Programmable Temperature Transmitter
Input: Thermocouple, RTD, Thermistor, Custom

Output: 0-2 mA to 0-20 mA, 20-0 mA, 0-1 V to 0-10 V, 10-0 V
  • PC Programmable
  • Reverse Output Programmable
  • Custom Input Linearization
  • Programmable Sensor Fault Response
  • Removable Plugs
  • 3.7 kV Input/Output/Power Isolation
  • Supply Voltage: 24-60 or 85-230 VAC/VDC
CE logo Data Sheet
Instructions
CE Declaration
V600Plus Software
V624
Top of page
Sineax V 604s Programmable Universal Transmitter
Two Inputs: ±1000 mVDC to ±300 VDC, ±50 mADC, Thermocouple, RTD, Thermistor or Potentiometer 0-5kΩ

Two Outputs (common ground): 0-5 mA to ±40 mA, 0-4 V to -12~+15 V
Relay: One Relay
Communications: Modbus new product
  • PC programmable
  • Unipolar or bipolar input and output
  • Reverse output programmable
  • Custom input linearization
  • Programmable math functions (+, -, x, Δ, min, max, mean, dx/dt)
  • Programmable sensor redundancy function
  • Programmable alarm relay with delay fucntion
  • 3.7 kV input/output/power isolation
  • Supply voltage: 24-230 VDC or 100-230 VAC
CE logo Brochure
Data Sheet
Instructions
Safety Instructions
CE Declaration
CB Manager Software
V604s

Top of page
Sineax VB 604s Programmable Universal Transmitter w. Remote I/O
Two Inputs: ±1000 mVDC to ±300 VDC, ±50 mADC, Thermocouple, RTD, Thermistor or Potentiometer 0-5kΩ

Two Outputs (common ground): 0-5 mA to ±40 mA, 0-4 V to -12~+15 V
Relay: One Relay
Communications: Control of Relay and Outputs via Modbus
new product
  • Ability to control relay and output via Modbus
  • PC programmable
  • Unipolar or bipolar input and output
  • Reverse output programmable
  • Custom input linearization
  • Programmable math functions (+, -, x, Δ, min, max, mean, dx/dt)
  • Programmable sensor redundancy function
  • Programmable alarm relay with delay fucntion
  • 3.7 kV input/output/power isolation
  • Supply voltage: 24-230 VDC or 100-230 VAC
Data Sheet
Instructions
Safety Instructions
CE Declaration
CB Manager Software
V604s

Top of page
Sineax V 604 Programmable Universal Transmitter
Input: 0-2 mV to ±40 V, 0-80 µA to -50-100 mA, Thermocouple, RTD, Thermistor, Potentiometer

Output: 0-5 mA to ±40 mA, 0-4 V to -12 to +15 V
  • PC Programmable
  • Unipolar or Bipolar Input and Output
  • Reverse Output Programmable
  • Custom Input Linearization
  • Programmable Alarm Relay
  • 3.7 kV Input/Output/Power Isolation
  • Supply Voltage: 24-60 or 85-230 VAC/VDC
CE logo Data Sheet
Instructions
CE Declaration
V600Plus Software
V 604
Top of page
Sineax VC 603 Programmable Universal Transmitter with Alarms
Input: 0-2 mV to ±40 V, 0-80 µA to -50-100 mA, Thermocouple, RTD, Thermistor, Potentiometer

Output: 0-5 mA to ±40 mA, 0-4 V to -12~+15 V
Relay: 1 DPDT, 2 SPDT
  • PC Programmable
  • 3 Independently Configurable Alarm Contacts
  • Unipolar or Bipolar Input and Output
  • Reverse Output Programmable
  • Custom Input Linearization
  • 3.7 kV Input/Output/Power Isolation
  • Supply Voltage: 24-60 or 85-230 VAC/VDC
CE logo Data Sheet
Instructions
CE Declaration
VC600 Software
VC 603
Top of page
Head-Mount Temperature Transmitters
Sineax VK 616 Temperature Transmitter
Input: Thermocouple, RTD

Output: 4-20 mA
  • PC Programmable
  • Programmable Sensor Fault Response
  • Isolated and Non-Isolated Versions
  • 12-30 VDC Loop-Powered
CE logo Data Sheet
Instructions
CE Declaration
V600Plus Software
VK616
Top of page
Sineax VK 626 HART Temperature Transmitter
Input: Thermocouple, RTD

Output: 4-20 mA HART logo
  • PC Programmable
  • HART Protocol
  • Programmable Sensor Fault Response
  • Isolated
  • 12-30 VDC Loop-Powered
CE logo Data Sheet
Instructions
CE Declaration
VK626
Top of page
Loop Power Supplies
Sineax B 840 Multi-Channel Loop Power Supply
Input: 24, 115, or 230 VAC

Output: 4-20 mA, 24 VDC
  • 4-Channel 4-20 mA, 24 V DC Versions
  • LED Monitor for Each Channel
  • Each Channel Isolated
  • Supply Voltage: 24, 115, or 230 VAC 50/60 Hz
  • 30 mA Current Limiter for Each Channel
CE logo Data Sheet
Instructions
CE Declaration
sineax b840
Top of page
Sineax B 812 Loop Power Supply with HART Communications
Input: 4-20 mA, 18 to 25.5 VDC, Source resistance 330 Ω

Output: 4-20 mA, 17 VDC no load, Permitted load: 750 Ω, 550 Ω with HART
Hart logo
  • 3.6 kV Input, Output, and Power Isolation
  • Red LED for Open and Short Circuit Fault Detection
  • Supply Voltage: 20-70 or 60-265 VAC/VDC (45-400 Hz for AC)
  • Designed for HART Protocol
CE logo Data Sheet
Instructions
CE Declaration
B 812
Top of page

Phone:  800-942-0315 or 847-918-3510   Fax:  800-949-7502 or 847-968-4891
apicb.com Home Page
Copyright © 1999-2012 Absolute Process Instruments, Inc.